3,097 research outputs found

    High-resolution tracking in a GEM-Emulsion detector

    Full text link
    SHiP (Search for Hidden Particles) is a beam dump experiment proposed at the CERN SPS aiming at the observation of long lived particles very weakly coupled with ordinary matter mostly produced in the decay of charmed hadrons. The beam dump facility of SHiP is also a copious factory of neutrinos of all three kinds and therefore a dedicated neutrino detector is foreseen in the SHiP apparatus. The neutrino detector exploits the Emulsion Cloud Chamber technique with a modular structure, alternating walls of target units and planes of electronic detectors providing the time stamp to the event. GEM detectors are one of the possible choices for this task. This paper reports the results of the first exposure to a muon beam at CERN of a new hybrid chamber, obtained by coupling a GEM chamber and an emulsion detector. Thanks to the micrometric accuracy of the emulsion detector, the position resolution of the GEM chamber as a function of the particle inclination was evaluated in two configurations, with and without the magnetic fiel

    Silicon Photo-Multiplier radiation hardness tests with a beam controlled neutron source

    Full text link
    We report radiation hardness tests performed at the Frascati Neutron Generator on silicon Photo-Multipliers, semiconductor photon detectors built from a square matrix of avalanche photo-diodes on a silicon substrate. Several samples from different manufacturers have been irradiated integrating up to 7x10^10 1-MeV-equivalent neutrons per cm^2. Detector performances have been recorded during the neutron irradiation and a gradual deterioration of their properties was found to happen already after an integrated fluence of the order of 10^8 1-MeV-equivalent neutrons per cm^2.Comment: 7 pages, 6 figures, Submitted to Nucl. Inst. Meth.

    u-RANIA: a neutron detector based on \mu -RWELL technology

    Full text link
    In the framework of the ATTRACT-uRANIA project, funded by the European Community, we are developing an innovative neutron imaging detector based on micro-Resistive WELL (μ\mu -RWELL) technology. The μ\mu -RWELL, based on the resistive detector concept, ensuring an efficient spark quenching mechanism, is a highly reliable device. It is composed by two main elements: a readout-PCB and a cathode. The amplification stage for this device is embedded in the readout board through a resistive layer realized by means of an industrial process with DLC (Diamond-Like Carbon). A thin layer of B4_4C on the copper surface of the cathode allows the thermal neutrons detection through the release of 7^7Li and α\alpha particles in the active volume. This technology has been developed to be an efficient and convenient alternative to the 3^3He shortage. The goal of the project is to prove the feasibility of such a novel neutron detector by developing and testing small planar prototypes with readout boards suitably segmented with strip or pad read out, equipped with existing electronics or readout in current mode. Preliminary results from the test with different prototypes, showing a good agreement with the simulation, will be presented together with construction details of the prototypes and the future steps of the project.Comment: Prepared for the INSTR20 Conference Proceeding for JINS

    A model to explain angular distributions of J/ψJ/\psi and ψ(2S)\psi(2S) decays into ΛΛ\Lambda\overline{\Lambda} and Σ0Σ0\Sigma^0\overline{\Sigma}^0

    Full text link
    BESIII data show a particular angular distribution for the decay of the J/ψJ/\psi and ψ(2S)\psi(2S) mesons into the hyperons ΛΛ\Lambda\overline{\Lambda} and Σ0Σ0\Sigma^0\overline{\Sigma}^0. More in details the angular distribution of the decay ψ(2S)Σ0Σ0\psi(2S) \to \Sigma^0\overline{\Sigma}^0 exhibits an opposite trend with respect to that of the other three channels: J/ψΛΛJ/\psi \to \Lambda\overline{\Lambda}, J/ψΣ0Σ0J/\psi \to \Sigma^0\overline{\Sigma}^0 and ψ(2S)ΛΛ\psi(2S) \to \Lambda\overline{\Lambda}. We define a model to explain the origin of this phenomenon.Comment: 6 pages, 7 figures, to be published in Chinese Physics

    A Cylindrical GEM Inner Tracker for the BESIII experiment at IHEP

    Full text link
    The Beijing Electron Spectrometer III (BESIII) is a multipurpose detector that collects data provided by the collision in the Beijing Electron Positron Collider II (BEPCII), hosted at the Institute of High Energy Physics of Beijing. Since the beginning of its operation, BESIII has collected the world largest sample of J/{\psi} and {\psi}(2s). Due to the increase of the luminosity up to its nominal value of 10^33 cm-2 s-1 and aging effect, the MDC decreases its efficiency in the first layers up to 35% with respect to the value in 2014. Since BESIII has to take data up to 2022 with the chance to continue up to 2027, the Italian collaboration proposed to replace the inner part of the MDC with three independent layers of Cylindrical triple-GEM (CGEM). The CGEM-IT project will deploy several new features and innovation with respect the other current GEM based detector: the {\mu}TPC and analog readout, with time and charge measurements will allow to reach the 130 {\mu}m spatial resolution in 1 T magnetic field requested by the BESIII collaboration. In this proceeding, an update of the status of the project will be presented, with a particular focus on the results with planar and cylindrical prototypes with test beams data. These results are beyond the state of the art for GEM technology in magnetic field

    E835 at FNAL: Charmonium Spectroscopy in pˉp\bar p p Annihilations

    Get PDF
    I present preliminary results on the search for hch_c in its ηcγ\eta_c\gamma and J/ψπ0J/\psi\pi^0 decay modes. We observe an excess of \eta_c\gammaeventsnear3526MeVthathasaprobability events near 3526 MeV that has a probability {\cal P} \sim 0.001toarisefrombackgroundfluctations.Theresonanceparametersare to arise from background fluctations. The resonance parameters are M=3525.8 \pm 0.2 \pm 0.2 MeV,MeV, \Gamma\leq1MeV,and 1 MeV, and 10.6\pm 3.7\pm3.4(br) < \Gamma_{\bar{p}p}B_{\eta_c\gamma} < 12.8\pm 4.8\pm4.5(br) eV.WefindnoeventexcesswithinthesearchregionintheeV. We find no event excess within the search region in the J/\psi\pi^0$ mode.Comment: Presented at the 6th International Conference on Hyperons, Charm and Beauty Hadrons (BEACH 2004), Chicago(Il), June 27-July 3,200

    Precision measurements of the total and partial widths of the psi(2S) charmonium meson with a new complementary-scan technique in antiproton-proton annihilations

    Full text link
    We present new precision measurements of the psi(2S) total and partial widths from excitation curves obtained in antiproton-proton annihilations by Fermilab experiment E835 at the Antiproton Accumulator in the year 2000. A new technique of complementary scans was developed to study narrow resonances with stochastically cooled antiproton beams. The technique relies on precise revolution-frequency and orbit-length measurements, while making the analysis of the excitation curve almost independent of machine lattice parameters. We study the psi(2S) meson through the processes pbar p -> e+ e- and pbar p -> J/psi + X -> e+ e- + X. We measure the width to be Gamma = 290 +- 25(sta) +- 4(sys) keV and the combination of partial widths Gamma_e+e- * Gamma_pbarp / Gamma = 579 +- 38(sta) +- 36(sys) meV, which represent the most precise measurements to date.Comment: 17 pages, 3 figures, 3 tables. Final manuscript accepted for publication in Phys. Lett. B. Parts of the text slightly expanded or rearranged; results are unchange

    Interference Study of the chi_c0 (1^3P_0) in the Reaction Proton-Antiproton -> pi^0 pi^0

    Full text link
    Fermilab experiment E835 has observed proton-antiproton annihilation production of the charmonium state chi_c0 and its subsequent decay into pi^0 pi^0. Although the resonant amplitude is an order of magnitude smaller than that of the non-resonant continuum production of pi^0 pi^0, an enhanced interference signal is evident. A partial wave expansion is used to extract physics parameters. The amplitudes J=0 and 2, of comparable strength, dominate the expansion. Both are accessed by L=1 in the entrance proton-antiproton channel. The product of the input and output branching fractions is determined to be B(pbar p -> chi_c0) x B(chi_c0 -> pi^0 pi^0)= (5.09 +- 0.81 +- 0.25) x 10^-7.Comment: 4 pages, 4 figures, Accepted by PRL (July 2003
    corecore